Portland Public Schools Boiler Conversions
Retrofit: Mechanical design services for the conversion of boiler fuel oil burners to natural gas burners.
-34 Schools, 84 boilers, 16,700 Boiler Horse Power
-Abatement, Demolition, and Decommissioning fuel oil systems and tanks
-Natural Gas line piping
-Combustion air modifications
-A.S.M.E CSD-1 controls
-Masonry chimney structural upgrades
-Stack rerouting and redesign
-Firebox modifications
-Natural Gas burner conversion
-Draft and induction fan modifications
OWNER: PORTLAND PUBLIC SCHOOLS
501 N Dixon Portland, OR 97227
Owner's Rep: Patrick LeBoeuf, Project Manager
P: 503.916.2000
La Grande H.S. Mechanical Upgrades
Retrofit: Mechanical design services for the renovation of mechanical HVAC and plumbing systems.
-Abatement/Demolition of existing equipment
-Natural Gas line piping
-New primary hydronic chilled water infrastructure
-Replacement of steam distribution system with new primary hydronic heating water piping
-Steam to hot water conversion for adaptation to existing boilers
-37 new fan coil systems and controls
-Energy modifications/controls for 20 existing fan/coil systems, 13 exhaust systems, and 33 terminal units
-Replacement of miscellaneous convectors
-New domestic hot water and storage tank heater
-24 new variable frequency drives
-Electrical infrastructural code upgrades
-Structural repairs and code upgrades
OWNER: LA GRANDE SCHOOL DISTRICT #1
1305 N Willow Street La Grande, OR, 97850
Owner's Rep: Chris Panike, Business Manager/Plant Operations Director
Joseph Waite, Bond/Facility & Operations Manager
P: 541.663.3214
La Grande Greenwood E.S. Upgrades
Retrofit: Mechanical design services for the renovation of mechanical HVAC systems.
-Abatement/Demolition of existing equipment
-Energy modifications/controls for 19 existing fan/coil systems, 6 unit heaters, and 21 convectors
-Two new split system multizone heat pumps
-20 new Dx split system air conditioners + associated electrical infrastructure
-Replacement of steam traps and pneumatic controls with DDC system
OWNER: LA GRANDE SCHOOL DISTRICT #1
1305 N Willow Street La Grande, OR, 97850
Owner's Rep: Chris Panike, Business Manager/Plant Operations Director
Joseph Waite, Bond/Facility & Operations Manager
P: 541.663.3214
La Grande Island City E.S. Upgrades
Retrofit: Mechanical design services for the renovation of mechanical HVAC systems.
-Demolition of existing equipment
-Energy modifications/controls for 5 existing fan/coil systems
-Two new split system multizone heat pumps
-5 new roof mounted split system heat pumps + roof structural supports + electrical upgrades
OWNER: LA GRANDE SCHOOL DISTRICT #1
1305 N Willow Street La Grande, OR, 97850
Owner's Rep: Chris Panike, Business Manager/Plant Operations Director
Joseph Waite, Bond/Facility & Operations Manager
P: 541.663.3214
La Grande Middle School Upgrades
Retrofit: Mechanical design services for the renovation of mechanical HVAC systems.
-Demolition of existing equipment
-Energy modifications/controls for 10 existing air handler systems
-New domestic hot water and storage tank heater
-16 new variable frequency drives
​
OWNER: LA GRANDE SCHOOL DISTRICT #1
1305 N Willow Street La Grande, OR, 97850
Owner's Rep: Chris Panike, Business Manager/Plant Operations Director
Joseph Waite, Bond/Facility & Operations Manager
P: 541.663.3214
Wells Fargo Bank Call Center Chiller Replacement
Retrofit: Mechanical design services for the replacement of central chillers.
-Two hydronic chillers, 750 tons total capacity
-Code compliance updates
-Additional safety controls and interlocks with existing equipment
-Exhaust fans
-Gas fired radiant heater
​
OWNER: WELLS FARGO BANK
18700 Walker Road Beaverton, OR 97123
Owner's Rep: Robert Brimer, Lead Operating Engineer (CBRE)
P: 503.614.6411
ODOT HVAC REPLACEMENT
R1 HEADQUARTERS
Retrofit: Mechanical design services for the replacement of Rooftop VAV/electric airhandlers.
-Two rooftop airhandlers, 122 tons total capacity
-Alternates for heat pumps and condensing furnaces
-Controls integration with existing building management system
​
OWNER: OREGON DEPARTMENT OF TRANSPORTATION
123 NW Flanders Portland, OR 97209
Kim Sorby, Facilities Coordinator
Lowell Youngblood, Facilities Maintenance Specialist
P: 503.731.8200
Pearson Packaging
Remodel: Mechanical and Plumbing design services for 13,000 square foot office space remodel.
-New ducting for existing Rooftop Gas Pack/Dx equipment
-New Split System / Multizone
-New plumbing
University of Idaho Residence Hall Dining Remodel
Remodel: Mechanical and Plumbing design services for 11,500 square foot dining hall/kitchen remodel.
-New kitchen Exhaust and Makeup Air System for food preparation area
-Plumbing modifications for food preparation and drink dispensers
OWNER: UNIVERSITY OF IDAHO
875 Perimeter Drive MS 2281 Moscow, ID 83844-2281
Owner's Rep: Douglas Morck, Owners Representative/Project Manager (SODEXO)
P: 562.519.3807
Tulalip Elders Center Kitchen Expansion
Remodel/Expansion: Mechanical and Plumbing design services for 1,800 square kitchen remodel/expansion.
-New kitchen Exhaust and Makeup Air System for food preparation area
-Plumbing modifications for food preparation and drink dispensers